Assessing zinc from a nail clipping using mono-energetic portable X-ray fluorescence
| dc.contributor.author | Fleming, David E.B. | |
| dc.contributor.author | Crook, Samantha L. | |
| dc.contributor.author | Evans, Colby T. | |
| dc.date.accessioned | 2025-01-09T19:29:10Z | |
| dc.date.available | 2025-01-09T19:29:10Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | A mono-energetic X-ray beam from a portable X-ray fluorescence device was used to excite characteristic X-rays from zinc in a series of nail clipping phantoms. Twenty nail clipping phantoms having equal zinc concentrations of ~40 µg/g, but with different physical characteristics, were measured individually for 300 s using a small diameter (~1 mm) X-ray beam. Energy spectra obtained from the measurements were analyzed using PyMca software. Zinc signal size varied widely between the different clippings, with a relative standard deviation of 41% observed in the combined signal from zinc Kα and Kβ characteristic X-rays. Three different normalization approaches were introduced to account for variation in the amounts of sample interrogated by the X-ray beam. All three approaches produced similar results, and successfully reduced the relative standard deviation to between 12% and 13%. A clear trend was still observed, however, between the normalized zinc signal and the thickness of clipping measured. To account for this effect, normalized signals were adjusted to calculate “thickness-corrected” values. The relative standard deviation of these thickness-corrected values was 6.2%. Reproducibility of measurement from individual clippings was excellent, with relative standard deviations on the order of 1%, with or without normalization. Overall, this new method of measuring zinc in nail shows promise for the assessment of zinc status in humans using a portable device. The method is sensitive, rapid, and requires only a single nail clipping. | |
| dc.identifier.doi | 10.1016/j.apradiso.2018.12.033 | |
| dc.identifier.issn | 0969-8043 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14662/752 | |
| dc.identifier.uri | https://doi.org/10.1016/j.apradiso.2018.12.033 | |
| dc.language.iso | en | |
| dc.publisher | Elsevier | |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | en |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.title | Assessing zinc from a nail clipping using mono-energetic portable X-ray fluorescence | |
| dc.type | Article |